For the daily use of the high-low temperature heat-humidity alternating current tester , some customers are not very skilled in use, resulting in some minor malfunctions in the occasional start-up operation of our equipment. The analysis is expected to be read carefully by our customers.
1. In the case of a power-hopping event, check the settings one by one. First set the machine to high temperature (40 degrees Celsius or 60 degrees Celsius), set the humidity to 0, and click Run to see if the machine will jump. If it is, it is a heating pipe. Short circuit, resulting in leakage, my driver will be protected will be the phenomenon of jump. If the heating tube is short-circuited, simply change the heating tube, which is very simple.
2. If the running high and low temperature humidity heat tester does not trip at high temperature, set the humidity and then continue to click Run to see if the machine trips. If it is tripped, the humidifying tube is short-circuited and leaks electricity. If this happens, simply unscrew the side bezel screws of the driver's device, remove the baffle, and you will see a humidifying bucket that pulls out the two wires above it and removes the 6 hexagonal cap screws on the cover. Remove, replace the humidification tube can be, when installed, the temperature probe needs to be bound on the humidification tube to prevent dry burning, over-temperature protection.
In this way, we solved the small faults of the tripping of the high-low temperature wet-heat alternating current tester during startup. Most of these minor faults were improperly used by the customer in the previous period. In the absence of water, the humidity was running and the humidification tube continued to dry. When the over-temperature alarm is not issued, the life of the humidification tube is damaged, resulting in such a minor failure.
Therefore, the customers are required to read the instructions carefully when operating the high-low temperature heat and humidity alternating test machine . Then, when the machine does not add pure water, and when the water is added, remember not to set the humidity so as to prevent the machine from alarming and damage the machine. Parts life.
Low Abrasive Slurry Pump series Centrifugal Slurry Pumps are cantilever Horizontal Centrifugal Slurry Pump, are designed for low abrasive, low density slurries. It is suitable for using in steel factory to transfer mill scale slurry, fly ash slurry, lime slurry etc.
Durable and solid is our always the first promise for the client. We always choose the right type and equipment for upon the clients request to customized the slurry pumps with our professional experience to reduce client`s cost and daily maintain cost.
Low Abrasive Slurry Pump
Low Abrasive Slurry Pump,Light Duty Slurry Pump,Lime Slurry Pump,Low Density Slurries Pump
Shijiazhuang BKDR Metallurgical Science & Technology Co.,Ltd , https://www.bkdrtech.com